Error Code E IU
Freezer In-Door Ice Maker Error (Craft Ice Heater Fault)
Moderate
Address soon - your appliance may not work properly
Also displayed as: E IU
How to Fix
- 1
Check all connections to the freezer in-door ice maker.
- 2
Measure upper heater (Red wire) resistance: expected 14.1–16.3Ω. If open (OL), replace upper heater assembly.
- 3
Measure lower heater (White wire) resistance: expected 14.1–16.3Ω. If open (OL), replace lower heater assembly.
- 4
If heater resistances are normal but harvest still fails, check icing fan operation and compartment temperature.
- 5
Verify compartment reaches below 0°F for ice harvesting.
This Error Applies To
LG LRFS28XB Series Refrigerators